BVZSK - FREON 12 (0-2,300 PPM) IN AIR, 36

  • MSDS: BVZSK
  • Manufacturer: GAS TECH INC
  • Product Name: FREON 12 (0-2,300 PPM) IN AIR, 36
  • National Stock Number: 6830-01-382-5101
Product Identification

Product ID:FREON 12 (0-2,300 PPM) IN AIR, 36
MSDS Date:06/11/1993
FSC:6830
NIIN:01-382-5101
MSDS Number: BVZSK

Responsible Party
GAS TECH INC
8407 CENTRAL AVE
NEWARK, CA 94560-3431
US

Emergency Phone: 800-535-5053

Info Phone: 510-794-6200

Cage: FO148

Contractor
GAS TECH INC. JOHNSON INSTRUMENT DIV
NEWARK, CA 94560-3431 US

Telephone: 510-794-6200

Cage: 51906

Ingredients

METHANE, DICHLORODIFLUORO-; (DICHLORODIFLUOROMETHANE)

CAS: 75-71-8

RTECS: PA8200000

Fraction By Weight: <0-0.23%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


AIR, REFRIGERATED LIQUID; AIR COMPRESSED (UN1002, DOT); AIR

RTECS: AX5271000

Fraction By Weight: 99.7%+

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CHLOROFLUOROCARBON (CFC) MATLS
HAVE PRODUCED SENSIT OF THE MYOCARDIUM TO EPINEPHRINE IN LAB
ANIMALS & COULD HAVE A SIMILAR EFT IN HUMANS. ADRENOMIMETICS (IE,
EPINEPHRINE) MAY BE CONTRA-INDICATE D EXCEPT FOR LIFE-SUSTAINING
USES IN HUMANS ACUTELY/CHRONICALLY EXPOSED TO CFCS . INHALATION
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: OF VERY HICH CONENTRATION MAY CAUSE
IRREGULAR HEART BEAT, ANGINA, DEATH. CHRONIC: NONE IDENTIFIED.
Medical Cond Aggravated by Exposure:CARDIOVASCULAR DISEASE.

First Aid

First Aid:INGEST: CALL MD IMMEDIATELY . EYES: IMMEDIATELY FLUSH WITH
POTABLE WATER FOR AT LEAST 15 MINUTES. SEEK ASSISTANCE FROM MD .
SKIN: FLUSH WITH COPIOUS AMOUNTS OF WATER. CALL MD . INHAL :
PROVIDE FRESH AIR OR OXYGEN AND CONSULT MD.

Fire Fighting

Extinguishing Media:USE METHODS APPROPRIATE TO SURROUNDING FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMP PRODS MAY INCL FLUORIDES,
CHLORIDES & PHOSGENE . COMPRESSED GAS CYLS MAY EXPLODE IN HEAT OF
FIRE. W/DRAW IMMED IN CASE OF RISING (SUPDAT)

Accidental Release

Spill Release Procedures:EVACUATE AND VENTILATE AREA.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:USE SAFE HNDLG & STORAGE PRACTICES FOR
THE HNDLG & STORAGE OF COMPRESSED GAS CYLS. DO NOT PUNCTURE. STORE
IN COOL, DRY AREA. EXPOSURE TO (SUPDAT)
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF CHLORIDES, FLUORIDES OR
PHOSGENE .

Exposure Controls

Respiratory Protection:NONE NECESSARY. NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:RECOMMENDED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKER GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ: SOUND FROM VENTING SAFETY DEVICE. HNDLG/STOR PREC:
TEMPERATURES ABOVE 150F MAY OPERATE EXCESS-PRESSURE VALVE.

Chemical Properties

Vapor Density:1.0-1.01
Solubility in Water:SLIGHT (25C)
Appearance and Odor:GAS.

Stability

Stability Indicator/Materials to Avoid:YES
SODIUM, POTASSIUM, BARIUM, MAGNESIUM OR ALUMINUM POWDERS, OIL IN HIGH
PRESSURE EQUIPMENT.
Stability Condition to Avoid:NONE IDENTIFIED.
Hazardous Decomposition Products:HYDROGEN FLUORIDE, HYDROGEN CHLORIDE,
PHOSGENE, CARBONYL FLUORIDE.

Disposal

Waste Disposal Methods:EMPTY CONTAINERS MAY BE DISCARDED AS METAL
REFUSE OBSERVING FEDERAL, STATE AND LOCAL REGULATIONS. DO NOT
INCINERATE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.